Reactor⚛️Dynamics — PWR Operator’s Manual Set

Plant: Pressurized Water Reactor (PWR)
Trainer: Reactor⚛️Dynamics educational plant simulator
Document set: Commercial-style operating manuals for training use
Revision: 24
Date: 2026-10-02


Purpose

This folder contains the operator’s manuals for the PWR unit of Reactor⚛️Dynamics. They are written in the style of commercial nuclear power plant operating manuals: numbered procedures, prerequisites, precautions, step-by-step actions, and acceptance criteria.

They cover:

  1. How to use the simulator (HMI, plant MODES, missions, tools).
  2. How to operate the plant (every control, normal evolutions, Mode 1, At Power through Mode 5, Cold Shutdown transitions).
  3. How to respond to alarms, upsets, and accidents (including Three Mile Island).

Primary operator paths: take the plant Mode 4, Hot Shutdown → Mode 1, At Power and Mode 1, At Power → Mode 5, Cold Shutdown (power operation to cold shutdown). See 05_MODE_TRANSITIONS.md procedures PWR-T20 and PWR-T21.

These manuals are written from the simulator as it is built, and they are the operator's manual for this plant: the in-app Manual shows exactly this text. They are training documents, not licensing basis documents for a real nuclear plant.


Document map

ChapterUse when…
01 · Plant general descriptionLearning what a PWR is and how this plant is modeled
02 · Simulator user guideStarting the trainer, the board layout, Free Play, Walkthroughs and Lessons
03 · Controls & indicationsOperating any individual control or reading any gauge
04 · Normal operating proceduresStartup, power operation, shutdown, system control procedures
05 · Mode transition proceduresMode 5, Cold Shutdown ↔ Mode 1, At Power; Mode 3, Hot Standby ↔ Mode 1, At Power; load changes
06 · Alarm response proceduresResponding to each annunciator
07 · Abnormal & emergency proceduresManaging every failure you can inject
08 · Accident study — TMI-2Studying the 1979 accident
09 · Setpoints & limitsLooking up trips, actuations, alarms, normal values
10 · GlossaryLooking up acronyms and terms
11 · Campaign ↔ manuals mapMatching missions to procedures
12 · Simulation physics & model scopeAsking what the sim actually computes, what it simplifies, and what it does not model at all
Revision historyChecking what changed in the manual set

Conventions used in these manuals

Procedure numbering

PrefixMeaningExample
PWR-N##Normal operationsPWR-N03 Approach to criticality
PWR-T##Plant MODE transitionsPWR-T03 Mode 3, Hot Standby → Mode 1, At Power; PWR-T20 Mode 4, Hot Shutdown → Mode 1, At Power
PWR-C##Control / system procedurePWR-C10 Pressurizer pressure control
PWR-A##Alarm responsePWR-A09 LO SUBCOOL
PWR-E##Abnormal / emergency (failure response)PWR-E01 Loss of main feedwater
PWR-X##Accident case studyPWR-X01 Three Mile Island

Callouts

CalloutMeaning
WARNINGAction or condition that can lead to core damage, trip, or severe plant upset
CAUTIONAction that can damage equipment, trip the unit, or violate a training limit
NOTEClarifying information; not a required action
[sim]Fully step-followable in this trainer
[narr]Narrative / context only — not step-followable on the board

Plant MODES (commercial numbering)

Convention: always write Mode N, Name (example: Mode 1, At Power).

MODEFull formCriteria (trainer)Trainer
1Mode 1, At PowerCritical, power > 5 %, RCS hot[sim]
2Mode 2, StartupCritical, power ≤ 5 %, RCS hot[sim]
3Mode 3, Hot StandbySubcritical, RCS hot[sim]
4Mode 4, Hot ShutdownSubcritical, intermediate T[sim]
5Mode 5, Cold ShutdownSubcritical, cold[sim]
6Mode 6, RefuelingHead detensioned / refuelingOut of scope

Do not confuse plant MODES with turbine load modes (Follow / Manual / Disconnected).

Mission ↔ procedure map: 11 · Campaign ↔ manuals map.

Units

These manuals quote US customary units first, with SI in parentheses — 2235 psi (15.41 MPa), 579.2 °F (304 °C). US first because that is what the PWR board reads; SI alongside because that is what the engine computes in, and what every setpoint in the source is written in.

QuantityUSSIConversion
Pressurepsi — always absoluteMPa× 145.038, whole psi
Temperature°F°C× 9/5 + 32, 1 dp
Temperature difference°F°C× 9/5, no offset — 1 dp
Condenser vacuuminHgkPa× 0.2953, 1 dp
Level, power, flow% / normalized — no conversion

Every pressure is absolute. The board and these manuals write psi and mean absolute pressure — the accumulator nitrogen, the containment and the steam generator included. A real plant's gauges mostly read psig, about 14.7 psi lower; where a manual quotes a real-plant document's number it keeps that document's psig and says so.

The difference row is not a footnote. Subcooling margin, leg ΔT, DNB margin, control deadbands and cooldown rates are temperature differences: this plant at full power carries a subcooling margin of about 42.7 °F (23.7 °C) — applying the absolute rule instead would print 74.7 °F and make a thin margin look comfortable.

Reactivity (pcm, Δk/k), startup rate (DPM), counts (cps), currents (A) and time have no US/SI distinction and are quoted once.

Instruments vs truth

You operate from instruments. Gauges, alarms, and automatic protection read instrumented values (with lag, noise, and possible failure). True physical state is available only as an explicit diagnostic overlay. This is deliberate — it is how Three Mile Island is teachable.

Control names

Controls are named by their on-screen labels. Internal command names appear only in the command cross-reference at the end of chapter 03.


New operator (first session)

  1. 02 Simulator user guide — get the board running
  2. 01 Plant general description — the plant and the Mode 1–6 naming
  3. 03 Controls & indications (skim)
  4. 05 Mode transitions — PWR-T20 (Mode 5, Cold Shutdown → Mode 1, At Power) and PWR-T03 (Mode 3, Hot Standby → Mode 1, At Power)
  5. 04 Normal operations — N01–N02, N04–N06, N14

Mode 5, Cold Shutdown → Mode 1, At Power → Mode 5, Cold Shutdown (the full story)

  1. 05 §3.0 PWR-T20 (Mode 5, Cold Shutdown → Mode 1, At Power)
  2. Operate in Mode 1, At Power (04 power procedures)
  3. 05 §4.0 PWR-T21 (Mode 1, At Power → Mode 5, Cold Shutdown)

Before free-play power maneuvers (Mode 1, At Power)

Before failure drills (typically Mode 1, At Power)


Where the numbers come from

Every number in this set is meant to match the simulator. Where a manual and the board disagree, the board is right and the manual is stale: tell us with Feedback in the top bar.


Scope disclaimer

In scopeOut of scope / narrative only
Mode 5, Cold Shutdown through full power, and backMode 6, Refueling
Reactivity, pressure, level, feed, turbineMore than one reactor coolant loop (this plant has one)
Every injectable failure, TMI, and the containment responseOffsite dose / source-term / release models
ESF auto arms, RPS tripsReal-plant Tech Specs / licensing

This is an educational lumped-parameter plant, not a full-scope replica of a licensed US PWR.

Chapters

These manuals are licensed CC BY 4.0 — see Legal. Training documents for an educational simulator, not licensing-basis documents for a real plant.